Air in the concentrate should be avoided by any means, as it upsets the
whole concentrate pre-treatment and drying.
It is possible to measure the content of air in the concentrate by using the
equipment as shown in Fig. 102. The apparatus is set under vacuum with the
glass stopper and valve B, C and D closed, and A open. The system is filled up
by NaCl solution by sucking it into the apparatus by a vacuum pump, leaving the
100 ml concentrate container empty and 1-2 ccm of air in the graduated glass
tube on the "air side".

Fig.
102 Laboratory measuring equipment for "Air in Milk
Concentrate"
The concentrate to be tested should now be filled into the 100 ml container,
which is then closed. The amount of air (should be 1-2 ccm) in the "air
container" is noted. Then the vacuum pump is started again, and the valve A is
opened slowly. By a proportional calculation of the expansion (shown in ml in
the graduated glass pipes) of the "known" amount of air in the "air" container
compared to the expansion of the un-known amount of air in the concentrate, it
is possible to calculate the content of ml of air/100 ml of concentrate.
Reference is made to Niro Analysis No. B 4 a.
Measurement of Insolubility Index is usually performed on milk powder, see
page 203. Should it for example not be possible to trace the problems with too
high insolubility Index by changing the drying parameters, it is recommended to
perform the test on the concentrate. The amount of concentrate to be used is
calculated as follows:
g concentrate = g powder x 100 / %TS of concentrate
g powder = 10 g skim milk, 13 g whole milk, or 6 g whey powder. The rest of
the procedure is as described for powder.