The CIP unit, comprises a basic unit all functions required for a reliable
cleaning process such as CIP supply, chemical dosing, heating, monitoring and
control.
The tanks being placed apart from the basic unit serve solely for detergent
supply. The modular structure of the CIP unit gives the necessary flexibility
for an adaptation to capacity and equipment requirements of the process. The
process independent system design allows free choice of the required cleaning
process.
The cleaning system type DICIP-E™ has been designed as central unit
for the automatic cleaning of production plants in the foodstuff sector. An
integrated, insulated buffer tank for caustic solution serves for the recycling
and for the increase in concentration of the caustic solution.
A cleaning program can be composed of the following
steps:
• Pre-rinsing with water. The returning pre-rinsing water is
eliminated.
• Caustic treatment, hot. The caustic solution is
redelivered into the caustic tank controlled via a conductivity meter in the
return pipe.
• Hot water. By means of a heater the water is heated up
to a preset temperature. Controlled via a conductivity meter and the
temperature metering the water is returned into the hot water tank.
•
Rinsing, cold with fresh water.
• Disinfection. In a fixed ratio
disinfectant is added to the fresh water and circulates through the object.
• Rinsing, cold with fresh water.
• Flow rates, temperatures
and times are adapted to the requirements of the object.
Special features:
• Economical use of caustic solution by recycling the caustic solution
and thereby reduction of waste water charge at the same time
•
Automatic increase in concentration of the caustic solution
•
Automatic control of the cleaning process
• Variable programs
Capacities
- CIP Depot Tanks: 5m3, 10m3, 15m3,
20m3, 30m3
- CIP Circuits: 2 × 20m3/h
Base
- CIP depot tanks, pumps, CIP Heaters
- Automation, pre-assembly of CIP supply & return valve
manifolds
Options
- Pre-rinse tank, hot water tank
- CIP concentrate dosing unit, disinfectant dosing unit
- Automatic depot tank CIP
- Filter in CIP return lines
- Variable speed drives for CIP supply pumps
- CIP heaters in CIP supply line(s)
- Additional CIP circuits 10m3/h, 20m3/h,
40m3/h, 60m3/h