Comparison of Energy Consumption in Different Evaporators

RSS Send link Print

EVAPORATOR

5-effect
TVR 

7-effect
TVR

1-effect MVR/
2-effect TVR

PRODUCT

Skim milk

Skim milk

Skim milk

Capacity, kg/h

15,000

15,000

15,000

Solids in/out, %

9/50

9/50

9/50

Evaporation, kg/h

12,300

12,300

12,300

Pasteurization temp., șC

90

90

90

Holding time, sec. 

30

30

30

Steam consumption, kg/h

1,610

1,190

375

Steam pressure, bar

10

10

10

Condensate, kg/h

13,400

13,400

12,800

Condensate temp., șC

54

51

22

Power consumption
- MVR, kW

-

-

150

- Motors, kW 

75

75

50

Cooling water cons., m3/h

32

3.5

2*)

Cooling water temp.,in/out, șC

28/35

28/35

12/50

Power cons. cool. tower, kW 

10

2.5

-

Residence time, min.

12

18

6

   
*) to be used only if the temperature of the raw milk is above 5șC.


2x3 high pressure fans for 2 MVR evaporators

Download brochure in PDF-format
Click anywhere in this box to view and/or download the brochure in Adobe PDF format.

Sales support
If you have any questions regarding this product call
+61-3-98754000
or write an email to
General Contact Form
GEA Process Engineering Pty. Ltd.
A.B.N. 26 000 689 618 .
49 Railway Road - P.O. Box 42 Blackburn - Victoria 3130 - Australia
Tel +61-3-9875-4000 . Fax +61-3-9894-2205 . © 2008 GEA .
Contact

For US inquiries, please visit the Niro Inc website: www.niroinc.com



© GEA 2012